Cold Room Wall & Ceiling Panels
Insulated panel systems designed for cold storage and temperature-controlled environments where thermal efficiency and enclosure integrity are critical. The panels are engineered to limit heat transfer, maintain consistent low temperatures, and support energy-efficient operation of refrigeration systems.
Product Specifications
| PARAMETER | SPECIFICATIONS |
|---|---|
| Full Form | Polyurethane Foam |
| Core Material | Rigid Polyurethane Foam |
| Thermal Conductivity | 0.022–0.024 W/m·K |
| Insulation Performance | Very Good |
| Fire Resistance | B2 / B3 (Flammable) |
| Smoke Generation | Higher |
| Density | 38–42 kg/m³ |
| Panel Thickness | 20–200 mm |
| Panel Width | 1060 mm |
| Panel Length | Up to 12–15 m |
| Top Sheet | PPGI / GI / Aluminium / SS |
| Bottom Sheet | PPGI / GI / Aluminium / Foil |
| Sheet Thickness | 0.35–0.60 mm |
| Wall & Ceiling Panels Profile | Plain / Ribbed |
| Weight (50 mm) | 10–12 kg/m² |
| Service Temperature | - 40°C to +80°C |
| Joints | Cam Lock |
| Cost | Lower |
| Applications | Factories, Warehouses, Sheds |
Key Performance Attributes
Outlining Essential performance parameters influencing insulation, strength, and installation efficiency.
High Thermal Insulation
Insulated panel construction limits heat transfer and supports stable low-temperature operation.
Airtight Panel Joints
Tight jointing systems reduce air infiltration, helping prevent temperature loss and condensation.
Moisture-Resistant Performance
Panel design supports operation in high-humidity, low-temperature environments typical of cold rooms.
Durable Cold-Environment Construction
Engineered to maintain structural integrity and insulation performance under continuous cold conditions.
Available Panel Joints
Mount’s panel joint configurations ensure precise alignment, secure interlocking, and effective load transfer, enhancing structural continuity, air and moisture tightness, and installation efficiency while maintaining long-term durability .

Roof Joint

Single Tongue & Groove Joint

Double Tongue & Groove Joint

Hidden Tongue & Groove

Camlock Joint

M Section
Advantages of the Cold Room Wall & Ceiling Panels
Designed for Low-Temperature Enclosures
Cold room panels are engineered specifically for refrigerated environments where maintaining internal temperature stability is critical.
Reduced Thermal Bridging at Panel Interfaces
Precision joint systems help limit heat ingress at vertical and ceiling junctions when properly installed and sealed.
Supports Vapor Control Strategies
Closed-cell insulation cores assist in reducing moisture migration through the panel body, an important factor in refrigerated facilities.
Ceiling Compatibility for Refrigerated Spaces
Panels are suitable for overhead installation in cold storage rooms, forming continuous insulated ceilings aligned with wall assemblies.
System Coordination with Refrigeration Components
Designed to integrate with cold room doors, floor insulation, and refrigeration systems to form a complete thermal enclosure.
Accessories
Mount Roofing & Structures provides engineered panel accessories designed to support installation accuracy, system compatibility, and enclosure performance across insulated panel applications.
These accessories are developed to integrate seamlessly with Mount panel systems, ensuring coordinated detailing, structural alignment, and long-term operational reliability across industrial, commercial, cleanroom, and cold storage projects.
Applications

Frozen Food Storage
Used in freezer rooms to maintain sub-zero temperatures for long-term food preservation.

Dairy & Milk Storage
Supports controlled cooling environments for dairy processing and storage.

Meat & Poultry Processing Units
Maintains low temperatures required during processing and storage operations.

Seafood Storage Facilities
Provides insulated enclosures for preserving fresh and frozen seafood.

Ice Cream Storage Rooms
Ensures stable freezing conditions for temperature-sensitive frozen products.

Fruit & Vegetable Cold Storage
Maintains controlled temperatures to extend shelf life of perishable produce.

Pharmaceutical Cold Storage
Used in temperature-controlled rooms for storing medicines and vaccines.

Beverage & Brewery Storage
Supports controlled environments for beverage storage and processing.

Hotel & Restaurant Walk-In Coolers
Applied in commercial kitchens requiring refrigerated storage rooms.

Logistics Cold Chain Warehouses
Used in large-scale distribution centres handling temperature-sensitive goods.

Ice Production Facilities
Provides insulated enclosures for ice manufacturing and storage.

Floral Storage Rooms
Maintains low temperatures to preserve flowers before distribution.
Why Choose Mount?
Mount Roofing & Structures manufactures cold room panel systems within a structured production environment supported by in-house engineering coordination. Temperature-controlled enclosures require consistency in core density and panel geometry to maintain insulation continuity.
Key capabilities include:
- 30+ Years of Combined Industry Experience
Technical expertise across insulated panels and steel building systems.
- Automated PUF Panel Production Lines
Ensures uniform core bonding, dimensional accuracy, and repeatable quality.
- 8.5 Million m² Annual Production Capacity
Supports large-scale industrial and infrastructure roofing projects.
- 460+ Skilled Workforce
Structured manufacturing, quality monitoring, and execution oversight.
- Exports to 89 Countries
Experience supporting cold storage, industrial, and infrastructure developments globally.

Frequently asked Question
They are insulated sandwich panels used to construct temperature-controlled cold storage enclosures.
They reduce heat transfer through insulation and airtight joints, limiting thermal loss.
Yes, they are used in both chiller and freezer applications, subject to insulation thickness selection.
Airtight construction reduces temperature loss, condensation, and refrigeration load.
Yes, improved insulation efficiency lowers refrigeration system operating demand.
Yes, they are designed to perform in humid cold room environments when properly installed.
Yes, they are designed for wall, ceiling, and partition applications within cold rooms.
Yes, they are widely used in food processing, cold storage, and pharmaceutical facilities.
Thickness depends on operating temperature, room size, and thermal performance requirements.
Temperature range, insulation performance, airtightness, humidity conditions, and regulatory requirements.